The New LPS-T8

LHY AUDIO Power Upgrade

Linear Power Upgrade Kit for Eversolo T8

From AC input to regulated DC output, give the T8 a more robust internal linear supply path.

LHY AUDIO LPS-T8 installed inside Eversolo T8
Product Introduction

A low-ripple, low-impedance internal supply path for Eversolo T8

LPS-T8 follows the real power path inside the player: the EMI AC filter board first treats line-borne interference, the LHY AUDIO hand-wound shielded toroidal transformer provides isolation, LT4320 rectification with Nichicon reservoir filtering and LT3042 linear regulation forms the DC stage, and OCC copper internal wiring completes the connection into the T8. It does not change the T8 digital platform; it focuses on supply noise, path impedance, and an internal installation that fits the chassis without cutting.

~90% lower measured ripple EMI / transformer / linear regulation path No chassis cutting
Why Upgrade

Why Upgrade To LPS-T8?

The T8 already uses a linear power architecture. LPS-T8 is for owners who want to take that foundation further: a production power design must balance cost, space, heat, reliability, and consistency, while LHY AUDIO focuses this upgrade specifically on power-supply engineering.

Product-Level Balance Linear Supply, Built To A Product Target A complete digital transport has to balance performance, cost, space, heat, reliability, and production consistency.
LHY AUDIO Expertise Dedicated Power-Supply Engineering LHY AUDIO applies its power design experience to filtration, transformer craft, rectification, regulation, and internal wiring.
Upgrade Goal Refresh The T8 From Its Power Foundation The goal is not to change the T8's digital platform, but to give it a cleaner, lower-ripple supply environment.

Common Owner Feedback

These are subjective listening notes from upgraded systems; the exact result will vary with system matching, cables, music, placement, and room conditions.

Detailed Engineering Data

From AC Input To Regulated DC Output

For buyers who want to verify the engineering, each stage is detailed with component choices, factory reference points, and the intended electrical benefit.

Step 01 AC Input Filtration

Dedicated EMI board with RIFA X2 / Y2 safety capacitors and large OFC-wound common-mode chokes.

Step 02 LHY AUDIO Transformer

LHY AUDIO hand-wound toroid with OFC copper, copper shielding, and controlled vibration damping.

Step 03 Regulated DC Output

LT4320 rectification, Nichicon filtering, and LT3042 regulation for lower-impedance DC delivery.

Step 04 OCC Copper Wiring

Single-crystal OCC copper harness completes the internal connection path after the regulated DC stage.

Bench Result ~90%

Controlled bench data shows ~90% lower measured ripple versus the stock PSU reference.

LHY AUDIO EMI AC filter board

EMI AC Filter Board

The EMI board treats the incoming mains before it enters the transformer and regulation stage. Its role is to reduce line-borne interference, preserve current delivery, and give the rest of the power chain a cleaner starting point.

ArchitectureAdvanced two-stage EMI filter design
Safety CapsRIFA X2 / Y2 safety-rated capacitors
ChokesLarge OFC-wound toroidal common-mode chokes ×2
VoltageManual 110V / 220V terminal jumper
Feature Factory PSU LHY AUDIO LPS-T8 Upgrade Result For The T8
Filtering Architecture Standard two-stage filter with generic safety capacitors. Upgrade
  • Advanced two-stage EMI filter
  • Dual common-mode chokes
  • RIFA X2 / Y2 safety-rated capacitors
BenefitImproves rejection of line-borne interference across a wider frequency range.
Safety Capacitors Standard industrial-grade safety capacitors. Upgrade
  • RIFA PME271 series
  • X2 / Y2 safety-rated capacitors
  • Designed for AC line filtering
BenefitSupports stable AC filtering and suppresses incoming mains noise before conversion.
Common Mode Chokes E-core chokes with small-gauge windings. Upgrade
  • Custom large toroidal chokes ×2
  • High-permeability cores
  • Thick OFC wire
BenefitStable current handling and lower winding resistance for efficient current delivery.
Voltage Switching Automatic relay switching via voltage sensing circuit. Upgrade
  • Manual 110V / 220V terminal jumper
  • Direct hard-wired AC path
BenefitFewer relay contacts in the AC input path reduce contact resistance and improve long-term reliability.
PCB And Build Standard 1.6mm immersion-gold PCB. Upgrade
  • 2.0mm PCB thickness
  • 2.5oz heavy copper
  • Immersion-gold finish
  • Hand-soldered power-path components
BenefitBetter current handling, thermal spreading, oxidation resistance, and solderability.
LHY AUDIO handcrafted toroidal transformer

LHY AUDIO Handcrafted Toroidal Transformer

To keep quality consistent and move beyond standard industrial transformer supply, the latest LPS-T8 uses an LHY AUDIO hand-wound custom transformer. The focus is winding craft, material purity, copper shielding, mechanical damping, and repeatable electrical behavior.

Core0.27mm high-flux silicon steel, above 19,000 Gauss
Windings6N primary and 7N secondary OFC copper
ShieldingSealed high-purity copper-foil shield
Verification12-hour full-load test, approx. 55°C at 22°C ambient
Feature Standard Transformer LHY AUDIO Handcrafted Upgrade Result For The T8
Core Material General industrial toroidal transformer core. Upgrade
  • 0.27mm imported high-flux silicon steel core
  • Magnetic flux above 19,000 Gauss
BenefitHelps resist saturation during dynamic current demand while reducing core loss and eddy-current loss.
Winding Material Standard industrial copper winding. Upgrade
  • 6N OFC primary winding
  • 7N OFC secondary winding
  • High-purity current transfer
BenefitLower DCR and faster current delivery help preserve density, smoothness, and dynamic control.
Winding Craft Machine-oriented production winding. Upgrade
  • Balanced hand-wound radial layout
  • Parallel winding construction
BenefitReduces distributed capacitance and leakage inductance, supporting better bandwidth and spatial stability.
Shielding And Damping Basic insulation and conventional wrapping. Upgrade
  • Sealed copper-foil shielding
  • Layered vibration-damping materials
  • High-temperature insulation
BenefitImproves EMI isolation and suppresses mechanical resonance inside the chassis.
Consistency Check Standard factory inspection. Upgrade
  • 12-hour full-power load verification
  • Approx. 55°C surface temperature at 22°C ambient
  • Output consistency within ±0.5%
BenefitSupports repeatable performance and long-term production consistency.
LHY AUDIO DC linear regulator board

DC Linear Power Regulator Board

After AC filtration and transformer isolation, the DC regulator board becomes the final precision stage. It rectifies, stores, regulates, and delivers a quieter, lower-impedance supply to the T8 digital audio platform.

RectifierLT4320 ideal full-wave rectifier
RegulatorADI LT3042 with PNP current boost
Main FilterNichicon KG 10,000µF / 50V ×4
PCB2.0mm board, 2.5oz copper, immersion-gold finish
Feature Factory PSU LHY AUDIO LPS-T8 Upgrade Result For The T8
Rectification MUR860 fast recovery diode bridge. Upgrade
  • LT4320 high-performance full-wave ideal rectifier
  • Heavy-copper PCB
  • WBT solder
  • Thick gold-plated connection pins
BenefitLower rectifier loss, less heat generation, and more stable current delivery under load.
Main Filter Capacitors 6800µF / 35V ×6 stock capacitors. Upgrade
  • Nichicon KG Hi-Fi grade capacitors
  • 10,000µF / 50V ×4
  • Higher capacity and voltage margin
BenefitGreater energy reserve and stronger ripple rejection for dynamic current demand.
Regulation Topology OPA277 op-amp plus MOS-FET regulation. Upgrade
  • ADI LT3042 ultra-low-noise linear regulator
  • PNP current boosting
BenefitLT3042 is specified for ultra-low-noise regulation, supporting a cleaner DC output stage.
Output Filtering 1000µF / 25V ×18 stock capacitors plus small WIMA film capacitors. Upgrade
  • Nichicon FW 1000µF / 25V ×12
  • WIMA film capacitors 0.1µF / 1000V ×3
BenefitAudio-grade low-ESR filtering improves high-frequency response and output stability.
PCB And Build Standard 1.6mm immersion-gold PCB. Upgrade
  • 2.0mm PCB thickness
  • 2.5oz heavy copper
  • Immersion-gold finish
  • Selected WBT solder
BenefitLower impedance, improved heat spreading, and more reliable long-term connection quality.
Measured Results

Microvolt-Level Ripple Under Bench Test Conditions

The upgrade is supported by measured electrical behavior. The stock Eversolo T8 PSU and LPS-T8 were compared at no load and under full load.

LPS-T8 bench measurement setup
Ripple Noise Comparison

Lower Noise Floor For The T8

Under measured bench conditions, LPS-T8 measured 2.577µV at no load versus the stock PSU at 21.13µV, and 3.556µV under full load versus the stock PSU at 32.09µV.

21.13µVStock PSU No Load
32.09µVStock PSU Full Load
2.577µVLPS-T8 No Load
3.556µVLPS-T8 Full Load
Stock No Load

21.13µV
Stock Full Load

32.09µV
LPS-T8 No Load

2.577µV
LPS-T8 Full Load

3.556µV
No-Load Result LPS-T8 No Load Compared against stock PSU under the same bench condition.
LPS-T8 Ripple2.577µVApprox. 87.8% lower than stock PSU
Stock PSU21.13µV
LPS-T8 no-load ripple measurement oscilloscope capture
LPS-T8 APx no-load capture2.577µV
Stock Eversolo T8 no-load RMS ripple measurement
Stock ReferenceOriginal PSU No Load21.13µV
Full-Load Result LPS-T8 Full Load Measured against the stock PSU reference under full-load conditions.
LPS-T8 Ripple3.556µVApprox. 88.9% lower than stock PSU
Stock PSU32.09µV
LPS-T8 full-load ripple measurement oscilloscope capture
LPS-T8 APx full-load capture3.556µV
Stock Eversolo T8 full-load RMS ripple measurement
Stock ReferenceOriginal PSU Full Load32.09µV
Kit And Installation

Clean Internal Upgrade, No Chassis Cutting

The kit follows the T8 internal replacement path with four upgrade components: EMI AC filter board, handcrafted transformer, DC linear regulator board, and OCC copper internal wiring, plus tools for careful installation.

LHY AUDIO EMI AC filter board
Part 01

EMI AC Filter Board

Dedicated input filter board for reducing line-borne interference before power conversion.

LHY AUDIO handcrafted toroidal transformer
Part 02

Handcrafted Transformer

LHY AUDIO hand-wound toroidal transformer with copper shielding and vibration damping.

LHY AUDIO DC linear regulator board
Part 03

DC Linear Regulator Board

Final rectification and regulation stage with high-capacity filtering and heavy-copper PCB construction.

OCC copper internal wiring for LPS-T8
Part 04

OCC Copper Internal Wiring

Prepared OCC copper harness for a clean internal connection path.

LPS-T8 installation tool kit
Tool Kit

Installation Tools

Included tools and gloves for careful installation work.

Installation reminder: Before installation, disconnect AC power completely and follow the official installation guide step by step. If you are not familiar with internal electronic installation, professional installation is recommended.
Download Installation PDF